雙正激變換器中高頻變壓器激磁電感的作用研究
作者:陳敏 馬 皓 徐德鴻 上傳時(shí)間:2004/12/23 11:58:16
摘要: 分析了雙正激DC/DC變換電路中的高頻變壓器的激磁電感對(duì)電路正常運(yùn)行的影響,導(dǎo)出了高頻變壓器能正常復(fù)位時(shí)的高頻變壓器的激磁電感、電路工作占空比、開(kāi)關(guān)頻率和開(kāi)關(guān)寄生電容之間的關(guān)系,并在3.5kW雙正激變換器中得到驗(yàn)證。
敘詞:雙正激DC/DC變換器 激磁電感
Abstract: The effect of the magnetizing inductance of the high frequency transformer in two-transistor forward converter is investigated in the paper. Relationship of the magnetizing inductance, duty cycle, switching frequency and parasitic capacitance between drain and source of main switches is found to satisfy magnetic resetting requirement of the transformer. Finally, simulation and experiment results are given to verify the analysis.
Keyword:Two-transistor forward converter magnetizing inductance
說(shuō)明:本站會(huì)員正確輸入用戶(hù)名和密碼進(jìn)行登錄系統(tǒng)后才能查看文章詳細(xì)內(nèi)容和參與評(píng)論。
--本文摘自《電源世界》,已被閱讀13167次
免責(zé)聲明:本文僅代表作者個(gè)人觀(guān)點(diǎn),與電源在線(xiàn)網(wǎng)無(wú)關(guān)。其原創(chuàng)性以及文中陳述文字和內(nèi)容未經(jīng)本站證實(shí),對(duì)本文以及其中全部或者部分內(nèi)容、文字的真實(shí)性、完整性、及時(shí)性本站不作任何保證或承諾,請(qǐng)讀者僅作參考,并請(qǐng)自行核實(shí)相關(guān)內(nèi)容。